Can You Charge a Lithium Floor Scrubber Battery in the Cold?
Can you charge a lithium floor scrubber battery below freezing? Charge temperature limits from seven maker documents, what heated packs fix, and a plan for cold docks and freezers.
Key takeaways
- No, not below freezing, unless the pack has a built-in heater. Trojan's GC2 lithium guide says never charge below 32 F (0 C), and Flux Power's C48 floor cleaning pack lists a charge range that starts at 32 F.
- The same packs run far colder than they charge. Both discharge down to -4 F (-20 C), so a lithium machine can scrub a cold room and still refuse the charger afterward.
- Above freezing, cold still slows charging. Trojan cuts the most a 36 V GC2 battery may take from 45 A to 23 A below 68 F, and to 13 A below 50 F. Once it locks out, it waits for 41 F (5 C) before charging again.
- A heated pack is not a freezer pack. Discover's DLP battery runs a 50 W heater from 1.4 F (-17 C) up, but its cells still charge only at 39.2 F (4 C) or warmer, and its BMS shuts off discharge below 1.4 F.
- Charge in a room above 50 F if you can, and read the machine manual too. Tennant's CS16 sets a 39.2 F charge floor, the T300e manual bans use below 32 F, and Kärcher says its B 50 W is not suitable for frozen floors in cold stores.
You cannot charge a standard lithium floor scrubber battery below freezing. Trojan's user guide for its GC2 lithium batteries says: "Never attempt to charge a battery when the temperature is below 32°F (0°C) or above 113°F (45°C)." Flux Power's C48 pack, sold for floor cleaning, lists the same 32 F floor. Try it anyway on Trojan's pack and its own electronics block the charge. The exception is a pack with a built-in heater, which warms its cells before it lets the charge in.
Two answers circulate. One says lithium handles the cold better than lead-acid. The other says lithium can't be charged in the cold. Both are true, and they answer different questions. The cold limit for running a lithium pack sits well below freezing. Trojan's and Flux Power's packs both discharge down to -4 F (-20 C). The limit for charging sits at freezing or above. So a lithium scrubber can clean a cold dock all shift and then refuse the charger at the end of it. That gap is where the confusion comes from.
The terms this answer turns on
Charge temperature range is the band of temperatures a battery may be charged in. Discharge temperature range is the band it may power the machine in. On a lithium pack they are printed as two separate lines. In every lithium document we read, the charge range is the narrower one.
BMS stands for battery management system. It is the electronics inside a lithium pack that watch each cell's voltage and temperature. If a limit is crossed, the BMS disconnects the pack or refuses current. A refusal because the cells are too cold is called an under-temperature lockout. Trojan calls it an under-temperature alarm.
Derating means the battery allows a lower charging current as it gets colder. Cell temperature is the temperature inside the pack, which is what the BMS measures. It lags behind the room. A pack carried in from a 20 F dock stays cold for a while, even in a warm room.
A heated pack has a heating element inside. It uses power from the charger, or from its own charge, to warm the cells to a temperature where charging is allowed.
Why the limit exists at all: CM Batteries, which builds lithium packs for cleaning machines, says a lithium-ion pack "may have an increased risk of fire when charged in cold winter temperatures." It gives the reason as the battery's "decreased ability to accept high-charge currents in cold temperatures."
One pack on a cold dock, walked through
Take one Trojan TR GC2 lithium battery in its 36 V version: 38.4 V and 45 Ah. Trojan's guide prints the most current it may take, by temperature:
- 68 to 113 F: 45 A
- 50 to 68 F: 23 A
- 32 to 50 F: 13 A
- Below 32 F: 0 A
Suppose the machine finishes a shift on a dock at 25 F and the operator plugs it in there. The pack is below 32 F, so it will not charge. Trojan says it will "disconnect from the charger and enter an under-temperature alarm." Charging stays disabled while the alarm is active. The guide's restart table puts the restart at 41 F (5 C), not at 32 F. So warming the pack just past freezing is not enough.
Now suppose the machine is moved to a 45 F room. Once the cells pass 41 F, charging resumes, but at no more than 13 A. Putting 45 Ah back at 13 A takes about 3.5 hours at best. The same charge at 45 A, in a room above 68 F, takes about 1 hour. In a 60 F room the ceiling is 23 A, or about 2 hours. These times are our arithmetic from Trojan's table. A real charger tapers near full, and it may put out less than these ceilings, so treat them as the fastest case.
The point of the walkthrough: below 32 F the answer is no, and between 32 F and 68 F the answer is yes, but slower. A fleet that charges in an unheated room loses hours every night, even on days when the room stays above freezing.
Charge temperature limits in seven maker documents
These are the limits as printed in the documents we read. Each figure belongs to its own battery or machine. Do not carry it over to another one.
| Document | Battery | Lowest charge temperature | Below it | Running (discharge or operating) range |
|---|---|---|---|---|
| Trojan TR GC2 lithium user guide (rev. 7/27/23) | LiFePO4 drop-in, GC2 size, 24, 36 or 48 V | 32 F (0 C), current cut below 68 F | Under-temperature alarm, restarts at 41 F (5 C) | -4 to 140 F (-20 to 60 C) |
| Flux Power C48 brochure | Lithium, 48 V, sold for floor cleaning | 32 F (0 C) | Not stated. Integrated heaters offered for cold use | -4 to 131 F (-20 to 55 C) |
| Discover DLP-GC2 manual (805-0027 Rev N) | LiFePO4 drop-in, GC2 size, with a 50 W heater | Cells 39.2 F (4 C). Heater runs from 1.4 F (-17 C) | Heater warms cells to 46.4 F (8 C), then charging starts | 1.4 to 143.6 F (-17 to 62 C) |
| CM Batteries 36 V cleaning machine pack | Lithium-ion, for robotic and automatic cleaning machines | 23 F (-5 C) | Low temperature protection | Down to -4 F (-20 C) |
| Tennant CS16 manual (PLDC04634 Rev 00, 03-2022) | Lead-acid, two 12 V 29 Ah | 39.2 F (4 C) | Not stated | Machine operates 39.2 to 104 F (4 to 40 C) |
| Tennant T300e manual (9014506 Rev 02, 10-2022) | Flooded or sealed AGM lead-acid | None stated. Charge at 80 F (27 C) or less | Not applicable | Do not operate below 32 F or above 110 F |
| Kärcher B 50 W manual (BTA-5765072-000-12) | Lead or 25.6 V 80 Ah lithium-ion | No separate figure. Machine range 41 to 104 F (5 to 40 C) | Not stated | 41 to 104 F. "Not suitable for cleaning frozen floors (e.g. in cold stores)" |
What the table shows
Standard lithium packs stop at freezing. Trojan and Flux Power both start the charge range at 32 F. Trojan adds the slower currents below 68 F and the 41 F restart. Flux Power's brochure prints the 32 F floor and offers "Integrated heaters for cold temperature applications." It does not say how far down those heaters reach.
Some packs go a little lower. CM Batteries lists "low temperature protection (as low as -5°C for charge and -20°C for discharge)" on its 36 V pack for cleaning machines. That is 23 F. It is a custom pack maker's figure, so check the label or data sheet of the pack in your machine. Do not assume your pack shares it.
The machine can be stricter than the battery. Tennant's CS16 is a small lead-acid machine. Its manual still says to charge only between 39.2 F and 104 F. The T300e manual sets no lower charge limit, but it says not to run the machine "below freezing 32F/0C." Kärcher's B 50 W comes with lead or lithium batteries. Its manual gives one range for the whole machine, 41 to 104 F. It also says the machine is not suitable for frozen floors in cold stores and must be stored frost-free. A lithium pack that can charge at 23 F does not make a machine with a 41 F limit fit for a freezer.
Heated packs: what the heater fixes and what it does not
Discover's DLP-GC2 shows how a heated pack works, because its manual prints every step. The BMS "does not allow charging when cells are below 4°C (39.2°F)." When the cells are between 1.4 F and 41 F, and the pack is on a charger or holds 50 percent or more, "energy is diverted to the internal heater until the battery reaches 8°C (46.4°F)." The heater is rated at 50 W. If the cells cool below 41 F again while the charger is connected, it turns back on.
So the heater solves the cold dock. Plug a Discover pack in at 25 F and it warms itself, then charges, with no one moving the machine. Warming takes time, and the manual gives no figure for how long.
It does not solve the freezer. Below 1.4 F the heater is outside its range. The BMS also shuts off discharge when cells drop below 1.4 F, and restarts it above 5 F. In a -10 F freezer, a pack whose cells reach room temperature can neither run nor heat itself.
One mismatch to know about. Discover's product page says "Charging from -20˚C / -4˚F." The manual's own specification table says the heater operates from -17 C (1.4 F), and the cells charge from 4 C (39.2 F). The manual is the document with the full specification, so we go by it.
A charging plan for cold docks and freezers
- Find your pack's charge range. Look at the battery label, the data sheet or the BMS app, not the machine brochure. You need the lowest charge temperature and the restart temperature, if one is given.
- Read the machine manual as well. Use the stricter of the two limits. The CS16 and B 50 W examples above show the machine can set the higher floor.
- Charge in a room above 50 F if you can. On Trojan's table that doubles the current ceiling from 13 A to 23 A, and above 68 F it reaches the full 45 A. A charging spot that sits just above freezing works, but slowly.
- Give the cells time. A pack carried in from the cold is still cold inside. If the charger shows no charge or a temperature fault, wait. Our battery not charging guide covers the lockout and the other causes of a charger that will not start.
- Plan freezer work around the charger. A machine that runs flat in a freezer cannot be topped up there. Our freezer floor guide covers the cleaners and the warm-up stop on the way out, and opportunity charging covers short charges between jobs.
For a machine parked in the cold for weeks rather than overnight, see winterizing a floor scrubber. That page covers storage, draining and antifreeze, not charging.
Where this stops applying
These figures come from seven documents. Other packs carry other numbers, and only your battery's own label or data sheet settles yours. A heated pack from one maker says nothing about a heated pack from another. Our worked charge times are ceilings, not test results. On ride-on machines with regenerative braking, Trojan says regen charging should also be reduced below 68 F, and that too much regen current in the cold "may force the battery to shut off." If a pack stays locked out after it has warmed up, treat it as a fault, not a temperature problem, and call the battery supplier. Where you charge matters as well as how cold it is. See where to charge a floor scrubber for ventilation and fire code rules.
Frequently asked questions
What is the lowest temperature to charge a lithium floor scrubber battery?
For most packs, 32 F (0 C). That is the floor in Trojan's GC2 guide and Flux Power's C48 brochure. One custom pack in our table charges down to 23 F (-5 C), and Tennant's CS16 machine sets 39.2 F (4 C). Check the label on your own pack.
Can a lithium scrubber run in a freezer?
The battery can run colder than it can charge: Trojan and Flux Power list discharge down to -4 F (-20 C). The machine may not be rated for it, though. The T300e manual bans use below 32 F, and Kärcher's B 50 W manual rules out frozen floors in cold stores.
Why does my lithium scrubber charge slowly in a cold room?
The battery limits current as it cools. Trojan's 36 V GC2 battery takes at most 45 A above 68 F, 23 A from 50 to 68 F and 13 A from 32 to 50 F.
Is lead-acid better for charging in the cold?
It depends on the machine. The T300e manual sets no lower charge limit for its lead-acid batteries, but the CS16 manual says to charge only at 39.2 F or above. Our lithium vs lead-acid comparison covers the wider choice.
Sources
- Trojan Battery, TR GC2 Series Lithium-Ion Batteries User's Guide (rev. 7/27/23): cdn.shopify.com
- Flux Power, C-Series C48 battery pack brochure: fluxpower.com
- Discover Battery, Lithium PROFESSIONAL DLP-GC2 manual 805-0027 Rev N: discoverbattery.com
- Discover Battery, Lithium PROFESSIONAL sell sheet 885-0027 Rev G: discoverbattery.com
- Discover Battery, Lithium PROFESSIONAL product page: discoverbattery.com
- CM Batteries, floor scrubber batteries page (36 V pack and cleaning equipment FAQ): cmbatteries.com
- Tennant CS16 Operator Manual PLDC04634 Rev 00 (03-2022): cdn.shopify.com
- Tennant T300e Operator Manual 9014506 Rev 02 (10-2022): cdn.shopify.com
- Kärcher B 50 W Operating Instructions BTA-5765072-000-12: kaercher-media.com